Furnace Blowing Cold Air? 8 Causes and What to Do

Updated November 22, 2026 · AirMaker HVAC Inc

The first cold night of the season is when most furnaces show their problems. You turn up the heat, the blower starts, and the air coming out of the vents is cold or barely warm. Here are the most common causes we find in Los Angeles homes, starting with the ones you can check yourself.

1. The thermostat fan is set to “On”

If the fan is set to On instead of Auto, the blower runs all the time, even between heating cycles. That pushes room-temperature air through the vents and feels cold.

What to do: set the fan to Auto and the mode to Heat, then raise the setpoint a few degrees above room temperature. Replace thermostat batteries if the screen is dim or blank.

2. The furnace just started

Most gas furnaces run the inducer motor, light the burners and warm the heat exchanger before the blower turns on. On some systems the first few seconds of air are cool.

What to do: wait two or three minutes. If the air warms up, the furnace is working normally.

3. A dirty air filter

A clogged filter chokes airflow. The heat exchanger overheats, the high-limit switch shuts off the burners as a safety measure, and the blower keeps running with no flame. The result is cold air and short cycles.

What to do: replace the filter. In most LA homes a 1-inch filter should be changed every one to three months, more often with pets or nearby construction.

4. The igniter or pilot is not lighting

Modern furnaces use a hot surface igniter. Older ones use a standing pilot. If the igniter is cracked or the pilot is out, the burners never light, and you get cold air or no heat at all.

What to do: look through the furnace’s sight glass for a blinking status light and note the pattern. The code chart is usually inside the furnace door. A failed igniter needs a technician.

5. A dirty flame sensor

The burners light for a few seconds and then shut off. This is the classic sign of a dirty flame sensor. The furnace cannot confirm a flame, so it shuts the gas off for safety and keeps the blower running.

What to do: this is a common, quick repair. A technician cleans or replaces the sensor and checks the full ignition sequence.

6. Overheating and the limit switch

Besides a dirty filter, closed or blocked vents, a weak blower motor or a failing capacitor can make the furnace overheat. The limit switch then shuts the burners off over and over.

What to do: open all supply vents and clear returns. If it keeps happening, book a repair. Repeated overheating is hard on the heat exchanger.

7. Gas supply or condensate problems

If other gas appliances work but the furnace does not, the furnace gas valve may be closed or failing. High-efficiency furnaces also make condensate water. A clogged drain or a failed condensate pump trips a safety switch and stops the burners.

What to do: make sure the gas valve at the furnace is open. If you see water around a high-efficiency furnace, turn it off and call for service.

8. Leaky ducts in the attic or crawlspace

If the furnace is making heat but some rooms still get cold air, the problem may be the ducts. In many LA homes, ducts run through hot attics and crawlspaces. A disconnected or torn duct dumps warm air where you never feel it and can pull cold air in.

What to do: a technician can inspect, seal or replace the ducts. Title 24 duct testing is required when ducts are replaced.

If you have a heat pump

Heat pumps blow cool air for a few minutes during a normal defrost cycle. If yours keeps blowing cold, read Heat pump blowing cold air in winter.

Safety first

  • If you smell gas, leave the home and call your gas company from outside.
  • If a carbon monoxide alarm sounds, get everyone outside and call 911.
  • Never cover or bypass furnace safety switches.

Learn the warning signs: Carbon monoxide from a furnace.

When to call a pro

Call for service if the filter and thermostat are fine and the furnace still blows cold, if you see a blinking error code, if the burners light and shut off, or if the furnace is 15 to 20 years old and keeps failing. Then it may be time to read When to replace a furnace.

AirMaker HVAC Inc repairs gas furnaces and heat pumps across Los Angeles and the San Fernando Valley. Every heating repair includes a heat exchanger inspection and a carbon monoxide check.

We get these calls from Calabasas and Santa Monica every winter and fix them on the first visit whenever the part is on the truck. In the West Valley we also handle furnace and heating repair in West Hills.

Need a licensed technician? AirMaker HVAC Inc serves Los Angeles and the San Fernando Valley. Call (818) 642-5278 or book online.

Please note: This article is general information for homeowners and businesses. It is not a substitute for an inspection by a licensed technician. Costs, timelines and code requirements vary by home, equipment and city. Do not open gas, electrical or refrigerant components yourself. If you smell gas, leave the building and call your gas company from outside. If a carbon monoxide alarm sounds, get everyone outside and call 911.

Need service? Let’s fix it.

Call, text or send a request and we will get back to you during business hours.

(818) 642-5278
Faster answer: text us a photo
📸 Text a photo

20620 Hatton Street, Winnetka, CA 91306
Monday–Friday, 9 AM–5 PM

5.0★★★★★136 Google reviews
“Vlad gave us great service. Didn’t try to sell us anything.”— Len Weed
“Vlad came out to get my heater going. He is exactly professional and knowledgeable.”— Serge S.

Phone or email — at least one.

Preferred day
Preferred time

We call you back to confirm the exact time.

Call (818) 642-5278